Hybrid PV solar off grid on grid tie energy storage inverter welder 48v 3kw 5kw 3000watts 5000watt with dual mppt controller

  • 1 - 20 Pieces
    $761.00
  • 21 - 50 Pieces
    $741.00
  • >=51 Pieces
    $711.00
Output Power:
3KW 5KW
Input Voltage:
48vdc
Output Voltage:
220V/230V
Samples:
3KW , 48vdc , 220V/230V
$1,200.00 /Piece | 1 Piece (Min. Order) | Buy Samples
Lead Time:
Quantity(Pieces) 1 - 1 >1
Est. Time(days) 7 Negotiable
Customization:
Customized logo (Min. Order: 10 Pieces)
Graphic customization (Min. Order: 20 Pieces)

More

Customized packaging (Min. Order: 20 Pieces) Less
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Xindun Power
Model Number:
XD-ES Inverter 3KW-5KW
Type:
DC/AC Inverters
Output Type:
Single
Output Current:
62.5a-104.2a
Output Frequency:
50Hz/60Hz
Size:
592*380*265mm
Weight:
36kg-45kg
Certificate:
CE RoHS
Product name:
Solar hybrid off grid on grid tie inverter
Waveform:
Pure sine waver inverter
Frequency:
Low frequency inverter
Capacity:
3kw 5kw inverter
Peak power:
9kw 15kw inverter
Display:
LCD+LED
Solar input:
2 route mppt
Battery type:
Lead-acid or lithium-ion battery
OEM:
Accepted
Application:
Solar Power System Home
Supply Ability
Supply Ability:
10000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
XD-ES Solar hybrid off grid on grid tie inverter generally packed with neutral wooden box.
3kw-5kw inverter package dimension(L*W*Hmm): 650*435*290mm, g.w. weight 40kg-49kg
Port
Foshan/Guangzhou/Shenzhen
Lead Time :
Quantity(Pieces) 1 - 1 >1
Est. Time(days) 7 To be negotiated

Xindun New Design Solar hybrid On/Off Grid Tie Energy Inverter 3kw 5kw

Click here for a lower inverter price. 10% discount for the top 10 consultations per day

 

Product Description
  Exclusive Feature 

  

 

  Technical parameter

 

Model: XD-ES 3KW 5KW
PV Input Max input voltage(At 25℃) 150V
MPPT tracking range 60V~120V(Recommend: The open circuit voltage should be less than 120V)
MPPT route number 2
Max input power 1960W/1960W 3360W/3360W
Battery Type of battery Lead-acid battery / Lithium-ion battery
Rated voltage 48V
Max charging current
(Can be set,Recommended 0.1C)
70A(PV)/35A(Mains)   120A(PV)/60A(Mains)  
Float voltage(Can be set) 55.2V
Charge voltage(Can be set) 56.8V
Charging method 3-stage/2-stage
AC Input Rated voltage 220V/230V
Input voltage range 187V~264V
Rated input frequency 50Hz/60Hz±5Hz
Islanding Protection ≤2S
Reconnection time 30S
AC output
 (off grid mode)
Rated output power 3KW 5KW
Rated output voltage 220V/230V
Output voltage accuracy 2%
Rated output frequency 50Hz/60Hz
Output frequency accuracy 1%
AC output
 (on grid mode)
Rated output power 3KW 5KW
Rated output current 13.6A 22.7A
Output voltage 187V~264V
Output frequency  47~52Hz/57~62Hz
Power Factor >0.99(Rated power)
Protection Output short circuit YES
Over load YES
Over-voltage/under-voltage YES
Over-frequency/under-frequency YES
Over temperature YES
Island protection YES
Regular Parameter Topology Transformer isolation
Protection level IP20
Display LCD+LED
Operating temperature -10℃~60℃(Derating above 45°C)
Storage temperature -20℃~60℃
Noise ≤60dB
Relative humidity 0%~95%(No condensation)
Highest altitude 2000m(More than derating)
Machine dimension(L*W*Hmm) 592*380*265
Package dimension(L*W*Hmm) 650*435*290
N.W(kg) 36 45
G.W(kg) 40 49
Installation Method Wall-Mounted

 

 

  On/Off Grid Inverter Detail

 

 

Using Method
  How to Use Solar On/Off Grid Inverter?

 

AC Priority Mode

 

1 When the mains power is normal and the current solar power generation is bigger than the load power, solar power will feed the load completely and the surplus solar power will feed the battery and transmit to the grid.

2 When mains supply is normal and the solar power is smaller than the load power, the insufficient part is supplemented by the mains supply; The solar and the mains supply feed the load together.

3 When mains supply is abnormal, the inverter changes to independent invert mode. When the solar power is bigger than the load power, the solar power will feed the load completely, and the surplus part will charge the battery. When the solar 

power is smaller than the load power, the insufficient part is supplemented by the battery; the batteries and the solar feed the load together.

4 When solar has no generating power, the mains supply will charge and store energy to the battery through the inverter.

5 When mains supply is abnormal and there is no solar, batteries will feed the load.

 

 

Battery Priority Mode

 

1 When the mains power is normal and the current solar power generation is bigger than the load power, solar power will feed the load completely and the surplus solar power will feed the battery and transmit to the grid.

2 When the solar power is smaller than the load power, the insufficient part is supplemented by the battery. The solar and the battery will feed the load together.

3 When solar power runs out or very little and the battery is placed to below 48 voltage, the discharge power of the battery will be linearly reduced. The insufficient part will be supplemented by mains supply. And when it reaches the low-voltage protection of the battery, the load will be completely fed by the mains supply .

4 When mains supply is abnormal, the inverter will work in the independent invert mode. The solar power will feed the load. And if the solar power is insufficient, it is supplemented by the battery.

Note: under the BATT mode, if there is no solar, mains supply won’t charge the battery.

 

 

 Peak-cutting and Valley-filling of power-using Mode

(This mode needs to work in battery priority mode)

 

This mode is suitable for the areas which have peak and valley electricity price. According to the electricity price in different periods, the corresponding time can be set to charge and discharge from the grid.

1 When the electricity price is low, mains supply charges the batteries;

2 When the electricity price is high, the batteries feed the loads.

 

Delivery & Payment
  Packaging & Shipping

 

Package
Wooden Box advised for Samples and batch to protect in transportations.

Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.

 

 

  Payment Term

 

T/T EXW 30% T/T in advance, balance paid before dispatch
FOB
CNF(CFR) 30% T/T in advance, balance paid against copy of B/L
CIF
L/C, D/A, D/P, Money Gram, Western Union, Paypal (Optional)

 

Related Products
  Hot sale inverters 
Company Information
  Why Choose Xindun Power? 

 

  About us 

 

Guangdong Xindun Power Technology Co.,Ltd

Factory Location

Foshan,Guangdong,China

Industry Experience

13-year manufacturer, 16-year trading, 8-year alibaba gold supplier

Product Range

solar inverter, hybrid inverter, ups, solar charge controller, solar power system, mini solar dc system
Main Market Africa, Middle East, Asia & South America. (Ukraine, Russia, Vietnam, Pakistan, Nigeria, Kenya, South Afriac, Ghana, Thailand, Philippines, etc.)
Factory 6000 Square Meters, 60+ workers
Department R&D, Production,  Sales, Marketing, Purchasing, QA, After-sale service department
Certificate ISO9001:2015, CE, IEC, etc.
Patent Software Paten, Design Patent, Project Pantent

 

 

  Workshop

  

  Production Process

 

 

  EXHIBITION & CUSTOMER

  

 

 

  CREDIBILITY

 

FAQ
  FAQ 

 

A: Are your inverters pure sine wave output?

Q: A Yes, All are true pure sine wave.

 

A: What kind of output you can do?

Q: Normally we produce inverter with 110V 115V 120V 220V 230V 240V, 50/60Hz self-adaption. If you have special requirements, please tell us for engineer consulting.

 

A: What' s the difference between low frequency and high frequency inverter?

Q: Low frequency inverter has various protections, strong ability to adapt to the environment. more reliable, with voltage regulation.

 

A: What's the difference between pure sine wave inverter and modified sine wave inverter?

Q: Pure sine wave output inverter is just as good as the Public power grid. Even better. Low repaired rate, long lifespan, Without harmonic pollution,  enviromental-friendly and appliances protected.

Modified sine wave output has a negative impact on appliances and can't load inductive load, such as air contition, refrigerator and etc. Certain motor control circuits don't like the modified wave.

 

A: What appliances your inverters can load?

Q: Our inverter can be used in household, Office, agricultural appliances and other inductive load such as refrigerator, air conditioner, water pump, etc.

 

A: Can you print our company logo on inverters, nameplates and packaging?

Q: Yes, we accept OEM orders.

 

A: How to choose a right inverter?

Q: Tell us your demand, then our sales will recommend a suitable inverter to you.

 

A: How to solve the technical problem?

Q: 24 hours after-service consultancy just for you and to make your problem to solveeasily.

 

A: Do I Need A Power Inverter?

Q: Actually, no. This is the only component of a solar energy system that is not absolutely required. However, if you don't use one, you will not have 220 or 230 volts AC and will have use battery power alone. This might be acceptable in a small RV or cabin, but most people want to use normal AC appliances.

 

A: What's The Difference Between 12, 24, And 48 Volt Inverters?

Q: This refers to the input voltage from the battery bank. The main consideration is that at higher voltages the current is less so that you can use smaller wires between your solar panel array and your battery bank. Of course, when you decide on a system voltage, the Solar Panels, Inverter, and Battery Bank all need to use the same voltage.

 

A: What to do if the product is broken? 

Q: If any product is faulty, you can send the picture or video to us, we sill study it and supply the spare parts of PCB board free for after sale service.